Skip to content

Latest commit

 

History

History
296 lines (218 loc) · 14.8 KB

gpu.md

File metadata and controls

296 lines (218 loc) · 14.8 KB

GPU Benchmarks

micromeasure can benchmark GPU work (e.g. cuBLASLt GEMM, CUDA streams) alongside CPU microbenchmarks. Three features work together to make GPU output less misleading than naive "wrap a kernel in Instant::now" timing:

  1. MeasurementDomain — tags a group as Cpu, Gpu, Io, or Mixed to control CPU-PMU diagnostics.
  2. MeasurementBackend — pluggable measurement window around the bench closure. The built-in CudaEventBackend records CUDA events on the default stream and uses device elapsed time as the sample duration.
  3. Per-sample custom metrics — bench_sample(...) lets the bench return a BenchSampleResult carrying operations plus named metrics (cuda_event_ms, tflops, ...). The runner aggregates them across samples and renders a custom metrics: table.

There is also a diagnostic replay pass for collecting invasive counters without contaminating timing. With the gpu-counters feature, that pass can use CUPTI/NVPerf range-profiler counters.

These features are independent: you can use MeasurementDomain::Gpu with the default backend, or a custom backend with MeasurementDomain::Cpu, etc. But they are designed to compose for GPU work.

Before writing a GPU benchmark, read GPU Benchmarking Sharp Edges. It documents the failure modes that motivated this design (host PMU counters don't describe the kernel, calibration assumes CPU-like chunk scaling, etc.).

Measurement domain

pub enum MeasurementDomain {
    Cpu,    // default: full PMU counters + historic diagnostics
    Gpu,    // suppress CPU-PMU bottleneck diagnostics; relabel scheduling line
    Mixed,  // emit CPU-PMU diagnostics with a [host] prefix
}

Set it on a group with g.measurement_domain(MeasurementDomain::Gpu).

What each domain does

  • Cpu (default): unchanged historic behaviour. Full PMU counters and the existing bottleneck diagnostics apply.
  • Gpu: CPU PMU data is treated as host-orchestration context, not as the primary bottleneck. CPU-PMU bottleneck diagnostics are suppressed entirely. The PMU scheduling byline is relabelled to host PMU (orchestration). Run-stability warnings (CV, outliers) are still emitted, because sample stability matters for any benchmark.
  • Mixed: CPU-PMU diagnostics are emitted but prefixed with [host], so the reader knows the signal is host-side context (e.g. a GPU benchmark that does meaningful host-side data layout between kernel launches). The PMU scheduling byline reads host PMU (mixed workload).

Interaction with emits_cpu_diagnostics

A backend can also opt out of CPU-PMU diagnostics via MeasurementBackend::emits_cpu_diagnostics() -> false. The runner suppresses CPU-PMU diagnostics when either:

  • stats.measurement_domain == Gpu, or
  • stats.emits_cpu_diagnostics == false.

Mixed keeps diagnostics (with [host] prefix) unless the backend also returns false from emits_cpu_diagnostics. This lets a CUDA event backend opt out for Mixed workloads where some host work is expected but you still do not want host-PMU bottleneck messages.

The gpu_domain and mixed_domain examples demonstrate the observable difference — see gpu_domain and mixed_domain.

Measurement backend

MeasurementBackend is an object-safe trait that owns the per-sample measurement window:

pub trait MeasurementBackend {
    fn begin(&mut self);
    fn end(&mut self);
    fn collect(
        &mut self,
        host_elapsed: Duration,
        ops: u64,
        chunk_index: usize,
        results: &mut Results,
        metrics: &mut Vec<MetricValue>,
    );

    fn measurement_label(&self) -> &'static str { "" }
    fn emits_cpu_diagnostics(&self) -> bool { true }
}

The runner calls begin immediately before the bench closure, end immediately after, then collect to materialize the measurement into the shared Results and any backend-specific metrics.

The duration contract

Backends decide what results.duration means:

  • LinuxPerfBackend and WallClockBackend set results.duration = host_elapsed (host wall-clock around the closure).
  • A GPU backend (e.g. CudaEventBackend) sets results.duration to the device event elapsed time and separately reports host_overhead_ms as a custom metric. Throughput/latency stats then describe the GPU kernel, not the host orchestration — which is usually what a GPU benchmark author wants.
  • If a backend leaves results.duration at Duration::ZERO, the runner falls back to host_elapsed to avoid divide-by-zero in throughput computation.

Backends must write ops into results.iterations (so the existing throughput/latency paths keep working) and set results.chunks_executed = 1 per sample.

Platform default

Platform Default backend
Linux LinuxPerfBackend (perf-event group + individual-counter fallback)
other WallClockBackend (timing-only)

Override per group with g.backend(|| Box::new(MyBackend::new())). The factory creates a fresh backend per benchmark run.

Built-in CudaEventBackend

Available behind the cuda feature (see Cargo.toml and build.rs for linking). It records cudaEventRecord in begin/end, synchronizes the stop event in end, computes elapsed in collect, and pushes:

  • cuda_event_ms — device event elapsed time
  • host_overhead_ms — host wall-clock minus device time
  • gpu_gib_s — when bytes_per_op > 0
  • gpu_tflops — when flops_per_op > 0

It uses device elapsed time as results.duration, and emits_cpu_diagnostics() == false.

CudaEventBackend::new(bytes_per_op, flops_per_op)  // CudaResult<Self>

On a CUDA error it records cuda_error_code as a metric instead of crashing the run.

See cuda_event_backend for a runnable example using real cudaMemsetAsync on the default stream.

Operation-reported device time

Some device APIs cannot put timing events around an opaque closure. WebGPU timestamp writes, for example, must be encoded in the command encoder that contains the measured pass. Such a benchmark can return BenchSampleResult::with_primary_duration(duration). The reported duration then drives primary latency, throughput, calibration, stability statistics, and persisted raw samples. Report host-visible submit/completion latency as a separate custom metric when that boundary matters.

OperationReportedDeviceBackend supplies the corresponding measurement label, suppresses CPU diagnostics, and records host_visible_ms automatically.

For a complete runnable wgpu reference — feature negotiation, pass-boundary timestamp writes, resolve/readback buffers, checked tick conversion, and an opt-in hardware self-check — see wgpu_timestamp_backend. It introduces no new backend type; the example owns its device, queue, and submissions.

Built-in GPU counter collector

Available behind the gpu-counters feature. GpuCounterCollector wraps NVIDIA CUPTI/NVPerf range profiling for diagnostic replay passes:

let mut collector =
    GpuCounterCollector::new(DEFAULT_NVIDIA_GPU_COUNTERS, "my_range")?;
loop {
    collector.begin()?;
    run_workload();
    if collector.end()? {
        break;
    }
}
for metric in collector.decode()? {
    result = result.push_metric(metric.to_metric_value());
}

The default metric set maps NVIDIA profiler metric names into stable micromeasure metric names:

NVIDIA metric micromeasure metric
gpu__compute_memory_throughput.avg.pct_of_peak_sustained_elapsed gpu_memory_peak_pct
lts__throughput.avg.pct_of_peak_sustained_elapsed gpu_l2_peak_pct
sm__throughput.avg.pct_of_peak_sustained_elapsed gpu_sm_peak_pct
sm__inst_executed_pipe_tensor.avg.pct_of_peak_sustained_active gpu_tensor_active_pct

GpuCounterError::into_diagnostic_result() converts counter setup, permission, metric, and collection failures into integer diagnostic metrics so a locked-down system can still run the timing benchmark.

See gpu_counters for a runnable example.

Writing a custom backend

The trait is object-safe; a runner can hold Box<dyn MeasurementBackend>. See custom_backend for a simulated CUDA event backend that needs no CUDA dependency — it records a fake device elapsed time and pushes cuda_event_ms / host_overhead_ms from collect.

The shape of a GPU backend collect is:

fn collect(
    &mut self,
    host_elapsed: Duration,
    ops: u64,
    _chunk_index: usize,
    results: &mut Results,
    metrics: &mut Vec<MetricValue>,
) {
    // Leaving has_* flags false suppresses CPU PMU rows and diagnostics.
    results.duration = self.device_duration;  // device event time
    results.iterations = ops;
    results.chunks_executed = 1;

    metrics.push(MetricValue::duration_ms("cuda_event_ms", self.device_duration));
    metrics.push(MetricValue::new("host_overhead_ms",
        (host_elapsed - self.device_duration).max(Duration::ZERO).as_secs_f64() * 1000.0, "ms"));
}

Leave has_cycles/has_instructions/... false to suppress CPU PMU rows in the stats table, and return false from emits_cpu_diagnostics() to suppress CPU-PMU bottleneck messages.

Per-sample custom metrics

bench_sample(name, f) registers a bench whose function returns BenchSampleResult:

fn my_gpu_bench(ctx: &mut GpuContext, chunk_size: usize, chunk_num: usize) -> BenchSampleResult {
    let device_s = ctx.run_kernel(chunk_size);
    BenchSampleResult::operations(chunk_size as u64)
        .with_primary_duration(Duration::from_secs_f64(device_s))
        .push_metric(
            MetricValue::duration_ms("cuda_event_ms", Duration::from_secs_f64(device_s))
                .with_display_name("CUDA event time"),
        )
        .push_metric(
            MetricValue::throughput_tflops("tflops", flops, device_s)
                .with_display_name("TFLOP/s"),
        )
}

The runner:

  1. Reads operations and routes it through the existing throughput/latency aggregation (Results.iterations).
  2. Collects metrics per sample and aggregates them into MetricSummary (mean, median, p95, min, max, contributing sample count).
  3. Persists the aggregated summaries in BenchmarkStats.metrics (JSON via the existing serde derive) and renders them in a custom metrics: table beneath the standard stats table.

Bench-function metrics and backend-pushed metrics are merged into one table. The aggregation key is (section, name, unit), so metrics with different sections or units are treated as distinct.

MetricValue

MetricValue carries name, value, unit, optional section, optional display_name, and a format hint (Number or Integer):

MetricValue::new("host_overhead_ms", overhead_ms, "ms")
MetricValue::duration_ms("cuda_event_ms", duration)       // helper
MetricValue::bandwidth_gib_s("gpu_gib_s", bytes, seconds) // helper
MetricValue::throughput_tflops("tflops", flops, seconds)   // helper
MetricValue::integer("selected_algo_id", algo_id, "id")   // integer format, no decimals

with_display_name(...) sets a human-readable label (e.g. "GPU bandwidth"); the aggregation key remains name. with_section(...) groups metrics in the table. Integer format rounds and never uses scientific notation — use it for algorithm IDs, device indices, workspace sizes.

See custom_metrics for a complete runnable example with duration_ms, throughput_tflops, and integer formats.

Diagnostic replay pass

Some counters are too invasive to collect in the timing loop (e.g. enabling CUPTI/NVPerf profiling changes kernel launch latency and may require replay passes). The diagnostic pass lets you collect them in a separate run that does not contaminate the timing statistics.

g.diagnostic_samples(3)
    .diagnostic_pass(my_gpu_counter_replay)
    .bench_sample("fp4_gemm", my_gpu_bench);

Behaviour:

  • Runs once after the normal timing samples, using the calibrated chunk size.
  • Metrics returned by the diagnostic pass are merged into the same custom metrics: table.
  • DiagnosticResult::new(section) applies section as the default for metrics that do not set their own section.
  • The diagnostic pass does not contribute to latency, throughput, CV, or outlier statistics, so it can collect invasive counters without contaminating normal timing.
  • Use g.diagnostic_samples(n) to repeat noisy diagnostic counters (default 1).
  • The diagnostic pass is fallible: return Err(DiagnosticError) and the failure is reported as a diagnostic metric rather than a timing failure.
fn my_gpu_counter_replay(
    ctx: &mut GpuContext,
    chunk_size: usize,
    _chunk_num: usize,
) -> Result<DiagnosticResult, DiagnosticError> {
    ctx.run_kernel_under_profiler(chunk_size)
}

DiagnosticResult is a section plus a Vec<MetricValue>, built fluently:

DiagnosticResult::new("profiler")
    .push_metric(MetricValue::new("kernel_launches", 42.0, "count"))

Metrics with no explicit section inherit the result's section.

Putting it together

A complete GPU benchmark group:

benchmark_main!(|runner| {
    runner.group::<GpuContext>("cuBLASLt FP4", |g| {
        g.throughput(Throughput::bytes(8))
            .measurement_domain(MeasurementDomain::Gpu)
            .backend(|| Box::new(CudaEventBackend::new(8, 16).unwrap()))
            .diagnostic_samples(3)
            .diagnostic_pass(my_gpu_counter_replay)
            .bench_sample("fp4_gemm", my_gpu_bench);
    });
});

The pieces compose:

  • MeasurementDomain::Gpu suppresses CPU-PMU diagnostics and relabels the scheduling line.
  • CudaEventBackend provides device-side timing, sets results.duration to the device event time, and pushes cuda_event_ms / host_overhead_ms / gpu_gib_s / gpu_tflops.
  • bench_sample lets the bench add its own metrics (e.g. selected_algo_id, bench-specific TFLOP/s).
  • diagnostic_pass collects invasive counters in a separate run.
  • GpuCounterCollector can be used inside that diagnostic pass to report CUPTI/NVPerf counters when the gpu-counters feature is enabled.

Limitations

  • Concurrent groups can apply a backend to the coordinated worker window. The built-in CudaEventBackend still records only the default stream. See GPU Benchmarking Sharp Edges.
  • CudaEventBackend uses the default stream only. Multi-stream work would need a custom backend or an extension.
  • GpuCounterCollector is NVIDIA-only and uses CUPTI/NVPerf. It may require driver counter permissions; permission failures should be treated as diagnostic availability failures, not benchmark timing failures.