Renogy BT Monitor (to MQTT)

A standalone Python application for monitoring Renogy solar devices via Bluetooth Low Energy (BLE) and publishing data to an MQTT broker with Home Assistant auto-discovery support. This code was developed for my 3 devices. Renogy Rover 40, Renogy 100 amp hour battery with heating module (RBT100LFP12SH-G1) and 1000 W pure sine wave inverter. Also this uses 2 BT adapters, a BT-1 and BT-2. The battery and inverter are connected via the hub, sharing the same BT-2 module. The BT connections are persistent, meaning once they connect, they will remain connected. The code also includes alarms and faults for each of the devices as attributes and "number of faults" sensors. The code also has a data validator for the charge controller (Rover 40) to prevent spikes in the data. The min, max and max change values can be adjusted in the data_validator.py file to suit your system.

Supported Devices

Device Type Model Examples BT Module Supported
Charge Controller Rover, Wanderer, Adventurer BT-1, BT-2 ✅
Battery RBT100LFP12SH-G1 (LiFePO4) BT-2 ✅
Inverter RINVTPGH110111S (1000W) BT-2 ✅

Features

  • 🔌 Connect to multiple Renogy BLE devices simultaneously
  • 📡 Publish data to MQTT broker
  • 🏠 Home Assistant auto-discovery (devices and entities appear automatically)
  • 🔋 Support for charge controllers, batteries, and inverters
  • 📊 Comprehensive sensor data (voltage, current, power, SOC, temperature, etc.)
  • 🔄 Configurable polling interval
  • 📝 Detailed logging
  • 🛡️ Automatic reconnection on connection loss

Dashboard Example

Included in dashboard yaml file.

Whole Dashboard

image

Battery Alarms

image

Data Validation Sensor (last 100 rejections, for Rover 40 Controller only)

image

Hardware Requirements

  • Raspberry Pi (Pi Zero 2W, 4 or 5) (or any Linux system with Bluetooth)
  • Bluetooth adapter (built-in or USB, like LM0101 long-range adapter)
  • Renogy BT-1 or BT-2 module(s) or both connected to your Renogy devices

Installation

1. System Dependencies (Raspberry Pi OS / Raspbian)

# Update system
sudo apt update && sudo apt upgrade -y

# Install Bluetooth and Python dependencies
sudo apt install -y python3 python3-pip python3-venv \
    bluetooth bluez libglib2.0-dev

# Enable Bluetooth service
sudo systemctl enable bluetooth
sudo systemctl start bluetooth

2. Clone or Download the Application

# Create directory
mkdir -p ~/renogy_monitor
cd ~/renogy_monitor

# Copy all Python files to this directory
# (main.py, ble_client.py, mqtt_handler.py, parsers.py, utils.py)

3. Create Python Virtual Environment

# Create virtual environment
python3 -m venv venv

# Activate virtual environment
source venv/bin/activate

# Install dependencies
pip install -r requirements.txt

4. Configure the Application

# Create sample configuration
python main.py --create-config

# Edit configuration with your settings
nano config.yaml

Configuration

Edit config.yaml with your device and MQTT settings:

# MQTT Broker Configuration
mqtt:
  host: "homeassistant.local"  # Your Home Assistant IP or hostname
  port: 1883
  username: "your_mqtt_user"   # Leave empty if no authentication
  password: "your_mqtt_pass"
  discovery_prefix: "homeassistant"
  topic_prefix: "renogy"

# Polling Configuration
polling:
  interval: 60  # Seconds between polls (10-600)

# Bluetooth Configuration
bluetooth:
  adapter: "hci0"  # Bluetooth adapter to use (hci0, hci1, etc.)
                   # Run 'hciconfig' to see available adapters
                   # Built-in Pi adapter is usually hci0
                   # USB adapters are usually hci1
                   # With two adapters the names can swap between boots:
                   # use the adapter's own address instead, as printed by
                   # 'hciconfig' (BD Address), e.g. "AA:BB:CC:DD:EE:01"
  auto_reset: true               # Reset the adapter by itself when a BT module
                                 # stays unreachable (needs passwordless sudo)
  reset_after_failed_polls: 3    # Polls in a row without a link before a reset

# Device Configuration
devices:
  # Charge Controller with BT-1 module
  - name: "Solar Charge Controller"
    mac_address: "XX:XX:XX:XX:XX:XX"
    alias: "BT-TH-FXXXXXXX"
    type: "controller"
    device_id: 255
    adapter: "bt1"

  # Battery with BT-2 module (Hub mode)
  - name: "Main Battery"
    mac_address: "XX:XX:XX:XX:XX:XX"
    alias: "BT-TH-XXXXXXXX"
    type: "battery"
    device_id: 48
    adapter: "bt2"

  # Inverter with BT-2 module (Hub mode)
  - name: "Power Inverter"
    mac_address: "XX:XX:XX:XX:XX:XX"
    alias: "BT-TH-XXXXXXXX"
    type: "inverter"
    device_id: 32
    adapter: "bt2"

# Logging
logging:
  level: "INFO"
  console: true

Device ID Guide

When using Hub Mode (multiple devices connected to one BT-2 via Communication Hub):

Device Type Standalone Hub Mode
Controller 255 96, 97
Battery 255 48, 49, 50
Inverter 255, 32 32

For separate BT modules (one per device), use device_id: 255.

Usage

Scan for Devices

Find your Renogy BT modules:

# Activate virtual environment
source venv/bin/activate

# Scan for nearby devices
python main.py --scan

Example output:

Found 2 Renogy device(s):

1. Name: BT-TH-FXXXXXXX
   MAC Address: XX:XX:XX:XX:XX:XX
   Signal Strength: -65 dBm

2. Name: BT-TH-ACCCCCCC
   MAC Address: XX:XX:XX:XX:XX:XX
   Signal Strength: -72 dBm

Run the Monitor

# Start monitoring (foreground)
python main.py config.yaml

# With debug logging
python main.py config.yaml --debug

Run as a System Service

Create a systemd service for automatic startup:

sudo nano /etc/systemd/system/renogy-monitor.service

Add the following content:

[Unit]
Description=Renogy BT Monitor
After=network.target bluetooth.target

[Service]
Type=simple
User=pi
WorkingDirectory=/home/pi/renogy_monitor
ExecStart=/home/pi/renogy_monitor/venv/bin/python main.py config.yaml
Restart=always
RestartSec=10

[Install]
WantedBy=multi-user.target

Enable and start the service:

sudo systemctl daemon-reload
sudo systemctl enable renogy-monitor
sudo systemctl start renogy-monitor

# Check status
sudo systemctl status renogy-monitor

# View logs
journalctl -u renogy-monitor -f

Home Assistant Integration

Automatic Discovery

Once the monitor is running and connected to your MQTT broker, devices and entities will automatically appear in Home Assistant under Settings > Devices & Services > MQTT.

Manual MQTT Configuration (Alternative)

If auto-discovery doesn't work, add sensors manually to configuration.yaml:

mqtt:
  sensor:
    # Battery SOC
    - name: "Solar Battery SOC"
      state_topic: "renogy/solar_charge_controller_xxxxxx/state"
      value_template: "{{ value_json.battery_percentage }}"
      unit_of_measurement: "%"
      device_class: battery

    # PV Power
    - name: "Solar PV Power"
      state_topic: "renogy/solar_charge_controller_xxxxxx/state"
      value_template: "{{ value_json.pv_power }}"
      unit_of_measurement: "W"
      device_class: power

    # Battery Voltage
    - name: "Solar Battery Voltage"
      state_topic: "renogy/solar_charge_controller_xxxxxx/state"
      value_template: "{{ value_json.battery_voltage }}"
      unit_of_measurement: "V"
      device_class: voltage

Availability

Every entity is marked unavailable in Home Assistant when either:

  • the monitor itself stops (Pi off, service crashed): the broker publishes the renogy/bridge/availability last-will message, or
  • a device stops answering for 3 polls in a row: renogy/<device>/availability goes offline.

So a dead link shows up as unavailable instead of frozen values. If you have automations that trigger on a fault or alarm count changing from 0, add not_to: [unknown, unavailable] to those triggers, otherwise going unavailable looks like a new fault:

- trigger: state
  entity_id: sensor.renogy_battery_active_alarms
  from: "0"
  not_to: [unknown, unavailable]

Energy Dashboard

The sensors are configured with appropriate state_class for energy tracking:

  • power_generation_today - Daily solar generation (Wh)
  • power_generation_total - Lifetime solar generation (Wh)
  • power_consumption_today - Daily load consumption (Wh)

Sensor Reference

Sensors marked diagnostic appear under Diagnostic on the device page. Static values (model, versions, serial) are read once when the monitor starts.

Charge Controller (Rover) Sensors

Sensor Unit Register Description
battery_percentage % 0x0100 Battery state of charge (voltage based)
battery_voltage / battery_current V / A 0x0101-0x0102 Battery voltage and charge current
controller_temperature / battery_temperature °C 0x0103 Controller and battery temperature
load_voltage / load_current / load_power V / A / W 0x0104-0x0106 DC load output
pv_voltage / pv_current / pv_power V / A / W 0x0107-0x0109 Solar panel input
battery_min_voltage_today / battery_max_voltage_today V 0x010B-0x010C Today's battery voltage range
max_charging_current_today / max_discharging_current_today A 0x010D-0x010E Today's peak currents
max_charging_power_today / max_discharging_power_today W 0x010F-0x0110 Today's peak power
charging_amp_hours_today / discharging_amp_hours_today Ah 0x0111-0x0112 Today's Ah
power_generation_today / power_consumption_today Wh 0x0113-0x0114 Today's energy
operating_days d 0x0115 Total operating days
over_discharge_count / full_charge_count - 0x0116-0x0117 Lifetime counters (as reported by the controller)
charging_amp_hours_total / discharging_amp_hours_total Ah 0x0118-0x011B Lifetime Ah
power_generation_total / power_consumption_total Wh 0x011C-0x011F Lifetime energy
load_status / charging_status - 0x0120 Load on/off and charging mode
fault_count / warning_count - 0x0121-0x0122 Active faults and warnings (details as attributes)
nominal_battery_capacity / system_voltage Ah / V 0xE002-0xE003 Configured capacity and system voltage (diagnostic)
battery_type - 0xE004 Configured battery type
over-voltage / charge limit / equalizing / boost (lithium: overcharge) / float (lithium: overcharge recovery) voltages V 0xE005-0xE009 Charge settings (diagnostic)
boost return / over-discharge recovery / under-voltage warning / over-discharge / discharge limit V 0xE00A-0xE00E Discharge settings (diagnostic)
firmware_version / hardware_version - 0x0014-0x0017 diagnostic

Battery Sensors

Sensor Unit Register Description
cell_N_voltage V 5001-5016 Cell voltages (one sensor per cell)
temperature_N, battery_temperature °C 5018-5033 Cell temperature sensors
environment_temperature °C 5037 Ambient temperature sensor
heater_temperature °C 5040 Heater temperature (heated models)
current / voltage / power A / V / W 5042-5043 Pack current (+charge/-discharge), voltage, power
remaining_capacity / total_capacity / soc Ah / Ah / % 5044-5047 Capacity and state of charge
cycle_count cycles 5048 Charge cycle count
charge / discharge voltage limit V 5049-5050 BMS limits (diagnostic)
charge / discharge current limit A 5051-5052 BMS limits (diagnostic)
alarm_count / warning_count - 5100-5108 Active alarms and warnings (details as attributes)
heater, charge/discharge MOSFET, fully charged on/off 5106-5107 Binary sensors
charging / discharging allowed on/off 5109 Binary sensors
serial_number / firmware_version - 5110-5117, 5130-5131 diagnostic
cell over/high/low/under voltage, charge and discharge high/low temperature V / °C 5200-5221 BMS warning ("high/low") and protection ("over/under") thresholds (diagnostic); all 22 thresholds are in the state JSON

Inverter Sensors

The RINVTPGH110111S answers only registers 4000-4009 and 4303-4326; the energy-storage inverter registers (4327+, 4398+, 4441+, 4543+) return "illegal address".

Sensor Unit Register Description
input_voltage / input_current / input_power / input_frequency V / A / W / Hz 4000-4001, 4009 AC input (0 when there is none)
output_voltage / output_current / output_power / output_frequency V / A / W / Hz 4002-4004 AC output
battery_voltage V 4005 Battery voltage at the inverter
temperature °C 4006 Inverter temperature
inverter_mode - 4102 normal / eco (sleep) / shutdown
fault_count - 4007-4008 Active faults (details as attributes)
eco_mode / beeper on/off 4007-4008 Binary sensors
firmware_version - 4319-4326 diagnostic

Register maps: Renogy Modbus documents collected in cyrils/renogy-bt discussion #94 (Rover Modbus, Lithium Iron Battery BMS Modbus Protocol V1.7, Inverter Modbus Protocol V1.8).

Connection Diagnostics (every device)

Published to renogy/<device>/connection after every poll. They stay available while the device itself is unreachable, as long as the monitor runs.

Sensor Meaning
Bluetooth Adapter Resets Automatic resets of the adapter this device uses, since the monitor started
Bluetooth Reconnects (24 h) Times the link to its BT module dropped and was re-established in the last 24 hours (devices on one BT-2 hub share this)
Failed Polls In A Row Polls without data; 0 when all is well, 3 or more shows as unavailable
Bluetooth Read Timeouts (24 h) Register reads without a reply in the last 24 hours
Last Connection Issue The latest problem in words, with its time and the adapter as attributes

The 24-hour counts start from zero when the monitor restarts. A few reconnects and timeouts a day are normal; an automation can alert on a reset (Bluetooth Adapter Resets going up) or on unusually high counts.

Troubleshooting

Device Not Found

  1. Ensure BT module is powered and connected
  2. Check Bluetooth service: sudo systemctl status bluetooth
  3. Verify adapter: hciconfig
  4. Try running with sudo: sudo python main.py --scan

Connection Timeouts

  1. Move closer to the device
  2. Increase CONNECTION_TIMEOUT in ble_client.py
  3. Check for Bluetooth interference
  4. Try a long-range Bluetooth adapter (like LM0101)

Using Two Bluetooth Adapters

Each BT module can use its own adapter, for example a long-range USB adapter for the module with the weaker signal and the built-in one for the other. Add bluetooth_adapter to that device (all devices on one BT-2 hub share an adapter):

bluetooth:
  adapter: "AA:BB:CC:DD:EE:01"            # default: the built-in adapter

devices:
  - name: "Solar Charge Controller"
    mac_address: "XX:XX:XX:XX:XX:XX"
    type: "controller"
    bluetooth_adapter: "AA:BB:CC:DD:EE:02"  # the USB adapter

Use the adapters' addresses (hciconfig, BD Address) rather than hci0 and hci1: with two adapters the names can swap between boots. If the adapter of a module is not present, that module uses the default adapter and the log says so. Compare the signal of each adapter with python main.py --scan --adapter hci1.

A USB adapter that stays DOWN on Raspberry Pi OS is usually blocked by rfkill (rfkill list). The monitor lifts that block when it resets an adapter it is configured to use; by hand: sudo rfkill unblock bluetooth.

A Device Stops Reporting While the Others Keep Working

When a BT module has had no working link for three polls in a row, the monitor resets the Bluetooth adapter and reconnects every module, which is what a service restart does. Look for resetting Bluetooth adapter in the log:

journalctl -u renogy-monitor | grep -i "resetting Bluetooth adapter"

A reset interrupts the other modules on the same adapter for about 15 seconds, so the wait between two resets doubles each time (10, 20, 40, then 60 minutes) and starts over once every module answers again. If resets do not bring the device back, the problem is at the module: check its signal (python main.py --scan) and unplug and replug the BT-1/BT-2. Set bluetooth.auto_reset: false to turn this off.

MQTT Connection Failed

  1. Verify broker IP/hostname and port
  2. Check username/password
  3. Ensure MQTT broker is running
  4. Check firewall rules

No Data Received

  1. Verify correct device_id (try 255 first)
  2. Check device type matches actual device
  3. Enable debug logging: --debug
  4. Check that Renogy app can connect (disconnect app first!)

Permission Denied (Linux)

# Add user to bluetooth group
sudo usermod -a -G bluetooth $USER

# Or run with sudo
sudo python main.py config.yaml

Battery Cell Alarms When Fully Charged

On a sunny day you may see cell_N_alarm on every cell from the time the battery reaches 100% until it starts discharging. The BMS raises it when a cell passes its Cell High-Voltage Warning threshold (3.5 V on the RBT100LFP12SH-G1, register 5201) and the Rover holds the battery at its boost voltage (for example 14.4 V = 3.6 V per cell). It reflects the charge voltage, not a fault: the protection trip (Cell Over-Voltage Protection, 3.7 V) is not reached. If it bothers you, lower the controller's boost/float voltage slightly, or ignore battery alarms in your automations while SOC is 100%.

Known Limitations

  • Only one BLE client can connect to a device at a time (close Renogy app first)
  • Raspberry Pi built-in Bluetooth may have limited range
  • Some older BT-1 modules may have compatibility issues

Changelog

1.4.0 (2026-11-22)

  • New: automatic recovery. When a BT module has had no working link for three polls in a row, the monitor resets the Bluetooth adapter and reconnects all modules, instead of failing until someone restarts the service. The wait between resets grows from 10 to 60 minutes. Settings: bluetooth.auto_reset and bluetooth.reset_after_failed_polls.
  • New: a BT module can use its own Bluetooth adapter (bluetooth_adapter per device), and adapters can be given by address so the choice survives the names swapping between boots. Each adapter is reset on its own, a missing adapter falls back to the default, and an rfkill soft block on a configured adapter is lifted.
  • New: connection diagnostics for every device in Home Assistant: adapter resets, reconnects and read timeouts in the last 24 hours, failed polls in a row, and the last connection issue. They keep updating while the device is unreachable.
  • A module that will not reconnect no longer delays the others: modules with a working link are polled first, and after the first failed poll a reconnect is tried once per poll instead of three times (about 35 s instead of 115 s).
  • A link lost in the middle of a poll is retried once, not once per remaining register.
  • Log: the link drops inside one connection attempt are counted in a single line instead of about 20 "Disconnected!" lines, and a timeout is named instead of logged as an empty error.

1.3.1 (2026-10-11)

  • Fix: stopping the service during a poll hung for about 90 seconds until systemd killed it (the poll kept reconnecting after shutdown had closed the Bluetooth connections). The poll loop is now cancelled first, then the monitor disconnects and marks itself offline.

1.3.0 (2026-10-11)

Checked against the Renogy Modbus documents (BMS protocol V1.7, Rover Modbus, inverter protocol V1.8):

  • Fix: battery warnings were read from the wrong register. The BMS reports warnings (cell/module high and low voltage, charge/discharge temperature) in 5107 bits 0-7; they were read from 5108, which holds per-cell voltage errors. The battery's Active Warnings sensor could never show a real warning, and a cell error was reported as the wrong warning.
  • Fix: battery "other alarms" (5104-5105) were decoded from the wrong bit positions (BMS board, ambient and heater temperature, charge/discharge current).
  • Battery serial number is 16 characters (5110-5117); the rest are version codes.
  • New: battery warning and protection thresholds (5200-5221), Rover nominal battery capacity and system voltage (0xE002-0xE003), inverter mode (4102).
  • Rover boost/float voltage sensors renamed for lithium mode, where these registers are the overcharge and overcharge-recovery voltages.

1.2.0 (2026-10-11)

  • 37 new sensors from registers the devices already provide (every register was checked against the real devices):
    • Rover: today's min/max battery voltage and peak currents, operating days, over-discharge and full-charge counts, lifetime charge/discharge Ah and lifetime consumption; the boost/float/equalizing and discharge voltage settings, firmware and hardware version (diagnostic).
    • Battery: cycle count, ambient and heater temperature, BMS charge/discharge voltage and current limits, serial number and firmware (diagnostic), and binary sensors for the charge/discharge MOSFETs, charging/discharging allowed and fully charged.
    • Inverter: firmware version (diagnostic).
  • Most of the Rover values were already in every reply but were not parsed.
  • Static registers (model, versions, serial) are read once instead of every poll.
  • Removed the "historical" read of register 60000 (0xEA60). It is not the 7-day history and returned settings.
  • Sensor reference in the README rewritten with register numbers. The inverter section listed sensors this model does not have.
  • Parser tests using register dumps from real devices.

1.1.0 (2026-10-11)

  • Fix: garbage readings from late replies. A reply that arrived after its request timed out was parsed as the next register block (for example max_charging_power_today = 70 published as 17,920 Wh generated today). Replies are now matched to the request (slave address, function, byte count, CRC) and stray bytes are discarded. This also protects hub mode, where battery and inverter share one BT-2.
  • Fix: the data validator could lock up. A genuine step change larger than max_change (PV voltage at sunrise) was rejected forever. A new level is now accepted after 3 consistent readings in a row.
  • Fix: sensors flashing "unknown". When one register block failed, all of its sensors went unknown until the next poll. The last values are kept instead.
  • New: availability. Entities go unavailable when the monitor stops (MQTT last will) or a device stops answering, instead of showing stale values.
  • Faster polling: waits for the complete reply instead of a fixed delay.
  • paho-mqtt 2.x callback API (removes the deprecation warning); unused asyncio-mqtt dependency removed.
  • Brings the repository in line with the version running in production (Bluetooth adapter reset on startup, battery charge/discharge enable bits fixed).

1.0.0 (2025-12-26)

  • Initial release.

Credits

This project is based on research and code from:

Modbus protocol documentation from Renogy/RongSi.

AI was used to create this project.

License

MIT License - See LICENSE file for details.

Disclaimer

This is not an official Renogy product. Use at your own risk. Renogy and all trademarks are property of their respective owners.