bme280: read dig_H4/dig_H5/dig_H6 from the right registers with sign extension (F-42) - #433
Merged
Merged
Conversation
This was referenced Nov 9, 2026
Mateusz-Krajewski
marked this pull request as ready for review
November 22, 2026 16:16
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Błąd
Współczynniki kalibracji wilgotności BME280
dig_H4,dig_H5(signed 12-bit wg datasheetu Bosch, 4.2.2) składane są wmw/i2c_service/controller/bme280/controller.cpp:293-294z bajtówuint8bez rozszerzenia znaku: dla E4 lub E6 ≥ 0x80 wynik to 2048…4095 zamiast liczby ujemnej, więcgetHumidityliczy błędną wilgotność (zależnie od egzemplarza układu; typowe chipy mają małe wartości, stąd utajone).Dodatkowo, znalezione przy poprawie: indeksy bajtów są przesunięte o jeden. Blok 0xE1–0xE8 (8 B):
dig_H5= E6<<4 | E5[7:4],dig_H6= E7. Kod używał dla H5 bajtów E7 i E6[7:4] (temp[6],temp[5]), a dla H6 bajtu E8 (temp[7], rejestr spoza kalibracji). Sama poprawka znaku na złych bajtach nie miałaby sensu, więc oba indeksy są poprawione w tych samych liniach.Przyczyna
Złożenie
uint8 << 4bez rzutu przezint8_t; błędne mapowanietemp[]na rejestry E1–E8.Poprawka
Dwie statyczne funkcje
BME280::ComposeDigH4(E4, E5)iComposeDigH5(E5, E6): bajt MSB rzutowany naint8_t(rozszerzenie znaku), ×16 | niższe 4 bity/górne 4 bity E5.dig_H5czyta E5/E6 (temp[4],temp[5]),dig_H6=int8_t(temp[6])(E7).dig_H4zachowuje bajty E4/E5 (temp[3],temp[4]). Poza tym wzory wilgotności bez zmian.Test
Nowy UT
//mw/i2c_service/tests:bme280_humidity_calib_test: wartości dodatnie bez zmian (0x135, 0x33, 2047), ujemne po rozszerzeniu znaku (E4=0xF0 → −256, 0x80 → −2048, 0xFF/0x0F → −1; to samo dla H5). cpplint = 0; build HW//deployment/cpu/ec:pkg //deployment/cpu/fc:pkgOK. Brak testu QEMU (sim nie ma modelu BME280).Ryzyko i sprawdzenie na sprzęcie
Zmienia się wynik
getHumidity— poprawia się względem datasheetu (H5/H6 realnie z właściwych rejestrów). Na BBB/hamowni: porównać odczyt wilgotności z referencyjnym higrometrem lub po zmianie kondensacji; sprawdzić, czy nie ma wartości poza 0–100 % (jest saturacja w sensorze). Jeśli którykolwiek egzemplarz miał wcześniej „poprawne” wartości dzięki przypadkowi (np. E8=0), po poprawce wynik może się zmienić o ułamki %RH.Pliki wspólne z innymi PR (konflikty przy scalaniu)
Przy scalaniu drugiego z pary zachować zmiany z obu stron (w
BUILD— wszystkie celecc_test):fix/F-28-ina219-init-write):mw/i2c_service/tests/BUILDfix/F-41-eeprom-writebyte):mw/i2c_service/tests/BUILDfix/F-29-adc-calibration):mw/i2c_service/tests/BUILDfix/F-40-pca9685-short-read):mw/i2c_service/tests/BUILDfix/F-22-pca9685-channel):mw/i2c_service/tests/BUILD